BJLYX - QUADRITECK DIGITEK RP STABILIZER

  • MSDS: BJLYX
  • Manufacturer: FR CHEMICALS
  • Product Name: QUADRITECK DIGITEK RP STABILIZER
  • National Stock Number: 6850-00N012042
Product Identification

Product ID:QUADRITECK DIGITEK RP STABILIZER
MSDS Date:12/01/1988
FSC:6850
NIIN:00N012042
MSDS Number: BJLYX

Responsible Party
FR CHEMICALS
524 S COLUMBUS AVENUE
MT VERNON, NY 10550
US

Emergency Phone: 800-456-7800;800-424-9300(CHEMTREC)

Info Phone: 800-456-7800

Cage: FRCHE

Contractor
FR CHEMICALS
MT VERNON, NY 10550 US

Telephone: 800-456-7800

Cage: FRCHE

Ingredients

WATER

CAS: 7732-18-5

RTECS: ZC0110000


AMMONIUM THIOCYANATE (SARA III)

CAS: 1762-95-4

RTECS: XK7875000

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


SODIUM ACETATE

CAS: 126-96-5

RTECS: AJ4375000


ACETIC ACID (SARA III)

CAS: 64-19-7

RTECS: AF1225000

OSHA PEL 10 PPM

ACGIH TLV: 10 PPM/15 STEL; 9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE:IRRIT OR BURNING POSS.HIGH CONC OF
ACETIC ACID VAPS CAN CAUSE EXCESS BLINKING,TEAR PRODUCTION,& EYE
DISCOMFORT.SKIN:IRRIT & BURNING POSS.INGEST:HIGH CONC OF ACETIC
ACID CAN CAUSE BURNING ABDOM PAI N,NAUS,VOMIT,SHOCK STATE,COLLAPSE.
CAUSES SEV IRRIT/CHEM BURNS TO THROAT,ESOPHAGUS & STOMACH.(SEE EFTS
OF OVEREXPOS)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:INHAL:IF HEATED HIGHLY IRRIT AMMONIA
VAPS WILL IRRIT THE THROAT.INHALING HIGH CONCENTRATIONS OF ACETIC
ACID CAUSES IRRIT,COUGHING,CHEST PAIN AND BREATHING
DIFFICULTY.PROLONGED INHAL MAY BE HA RMFUL.
Medical Cond Aggravated by Exposure:NONE KNOWN

First Aid

First Aid:EYE:FLUSH WITH WATER FOR 15 MINUTES. GET MD. SKIN:REMOVE
CONTAMINATED CLOTHING. WASH EXPOSED AREA THOROUGHLY WITH WATER. GET
MD. WASH CONTAMINATED CLOTHING BEFORE RE-USE. INGEST:IF CONSCIOUS,
GIVE 2 G LASSES OF WATER. DO NOT INDUCE VOMIT. GET MD IMMED.
INHAL:REMOVE TO FRESH AIR. IF ADVERSE SYMPTOMS DEVELOP, GET MD.

Fire Fighting

Flash Point:NONE
Extinguishing Media:NONE (MFR). SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:FIRE OR EXCESSIVE HEAT MAY RELEASE
AMMONIA.

Accidental Release

Spill Release Procedures:NEUTRALIZE WITH MILD ALKALI.DILUTE WITH WATER
(1+10 RATIO).SEWER DISPOSAL MAY BE SUITABLE UNDER AN APPROVED
PERMIT AFTER SILVER RECOVERY.CONSULT LOCAL REGULATORY AGENCIES FOR
APPROPRIATE WASTE DISPOSA L METHODS.
Neutralizing Agent:SEE ABOVE

Handling

Handling and Storage Precautions:STORE THIS PRODUCT AT ROOM
TEMPERATURE. LAB COAT.
Other Precautions:CONTACT LENS WEARERS SHOULD WEAR REGULAR GLASSES.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:GENERAL AND LOCAL RECOMMENDED.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYE WASH & DELUGE SHOWER
Work Hygienic Practices:NONE (MFR). WASH THOROUGHLY AFTER HANDLING AND
BEFORE EATING, DRINKING, SMOKING OR USING SANITARY FACILITIES .
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

HCC:C1
Boiling Pt:B.P. Text:>212F,>100C
Spec Gravity:1.15
pH:4.4
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR TO SLIGHT YELLOW SOLUTION; VINEGAR ODOR
Percent Volatiles by Volume:>75

Stability

Stability Indicator/Materials to Avoid:YES
ALKALI
Stability Condition to Avoid:NONE
Hazardous Decomposition Products:AMMONIA

Disposal

Waste Disposal Methods:SEE SPILL/RELEASE PROCEDURES.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.